Material platform · MSN-7B

MSN-7B Heat-Sealable Oral Pouch Nonwoven

A 32 gsm / 34 gsm nonwoven material platform for oral pouch sample review and production-line qualification. Performance should be validated against the target application, pouch format, fill, equipment and process conditions.

Evidence status

Separate controlled product data from qualification assumptions

Specified

34 gsm data

Current manufacturer-issued values are published below with their current scope.

Qualification Item

32 gsm performance

Available for sample review; do not transfer all 34 gsm values by assumption.

Tested

SGS support

Scope-specific 2025 reports cover the named material/sample and must be read by model, date and conclusion type.

Document Review

Method references

Two TDS method references require verification against original test records; no replacement method number is guessed.

Current 34 gsm manufacturer TDS values

Numeric values below reproduce the current manufacturer-issued 34 gsm limits. Where the existing TDS method reference is under review, the website intentionally does not present it as a validated test method.

ParameterCurrent 34 gsm valueMethod / status
Model conventionMSN-7B-34-XX-YYXX = nominal width; YY = nominal roll length
Basis weight34 ± 2 g/m²ISO 9073-1
Thickness0.16–0.20 mmISO 9073-2
Tensile strength — MD≥45 N / 5 cmISO 9073-3
Tensile strength — CD≥5.5 N / 5 cmMethod reference under review
Heat seal strength≥13 N / 5 cmMethod reference under review
Recommended shelf life24 monthsUnder appropriate storage conditions
Basis-weight options32 / 34 gsmMatch the option to its current qualification documents
Controlled TDS: request the current qualification copy before a formal supplier approval or line-validation record. The website does not modify the manufacturer’s source document or invent replacement method numbers.

Where MSN-7B enters the qualification process

Converting

Nominal width, roll format, feeding and line stability should be confirmed on the target equipment.

Sealing

Use machine-specific trial settings and acceptance criteria; do not assume one universal temperature or dial position.

Finished pouch

Review powder retention, wet integrity, appearance, mouthfeel, handling and consistency with the actual fill system.

Current documentation path

  • MSDS and manufacturer-issued food-contact / material statements.
  • 2025 SGS report recording a Pass for FDA 21 CFR 176.170 chloroform-soluble extractives for the tested MSN-7B sample.
  • Separate 2025 SGS ingredient review with reference to FDA 21 CFR 175.105; not a blanket FDA approval.
  • Historical evidence is kept separate from the current MSN-7B evidence set.

Run a 32 / 34 gsm comparison

Share the pouch size, required roll width, machine, fill condition and trial goal so the sample set can match the project.

Request qualification samples